Setting Travel Limits: Chamberlain Whisper Light Guide

how set travel limit chamberlain whisper light

Setting the travel limits on your Chamberlain Whisper Drive Plus is crucial for ensuring your garage door opens and closes smoothly and securely. By properly setting these limits, you enhance the security of your garage and optimise the performance of your garage door opener. In this article, we will guide you through the step-by-step process of setting the travel limits for different models of Chamberlain Whisper Drive Plus, including those with Chamberlain/Liftmaster Security 2.0+ Technology, Purple and Black or Black and Yellow Buttons, and Older Style with Plastic Screw Adjustments. We will also discuss the importance of setting the force limits and share essential safety tips for adjusting your garage door opener.

Characteristics Values
Travel limits Regulate the points at which the door will stop when moving up or down
Adjustment buttons Located on the back of the opener
Safety A properly installed safety reversal system is crucial to prevent serious injuries or accidents
Safety reversal system test The door MUST reverse on contact with a 1-1/2" (3.8 cm) high object or a 2x4 laid flat on the floor
Force adjustments NEVER use force adjustments to compensate for a binding or sticking garage door
Open position Ensure the door opens high enough for your vehicle
Down position Adjust the door to the desired closed position
Pressure Toggle the door back and forth to reach the desired closed position with the right pressure
First Type Chamberlain & Liftmaster Security 2.0+ Technology
Second Type Purple and Black or Black and Yellow Buttons
Third Type Older Style with Plastic Screw Adjustments

quartzmountain

Chamberlain Whisper Drive Plus: Setting the travel limits

Setting the travel limits on your Chamberlain Whisper Drive Plus is important for ensuring that your garage door stops at the right points when moving up or down. By properly setting these limits, you enhance the security of your garage and ensure the door operates smoothly without any potential risks.

Chamberlain/Liftmaster Security 2.0+ Technology

If you have a Chamberlain/Liftmaster opener with Security 2.0+ Technology, you can set the travel limits using the up and down arrow buttons on the back of the opener. Here’s a step-by-step guide:

  • Start with the garage door in the down position.
  • Press and hold the adjustment button (located between the up and down arrow buttons) until the up arrow button starts blinking.
  • Use the up and down arrow buttons to adjust the door to your desired open and closed positions.
  • Press the adjustment button again to complete the travel limit adjustments.

Older Chamberlain/Liftmaster Opener with Purple and Black or Black and Yellow Buttons

For older Chamberlain/Liftmaster openers with purple and black or black and yellow buttons, you need to program the travel limits during the initial installation. Here’s how to do it:

  • Press and hold the black button until the yellow LED starts blinking, then release.
  • Adjust the door to your desired open position using the black button.
  • Press the wall button or remote to set the up limit.
  • Hold the purple button until the door reaches your desired closed position.
  • Set the down limit using the wall button or remote.

Older Style with Plastic Screw Adjustments

If you have an older style Chamberlain/Liftmaster opener with plastic screw adjustments, follow these steps to adjust the travel limits:

  • Locate the white travel limit adjustment screws on the side of the motor.
  • Start with the door closed.
  • Use the up/open limit adjustment screw to set the desired fully open position.
  • Adjust the down/close limit using the corresponding screw.
  • Run the door through several open and close cycles to ensure it opens and closes to the desired positions.

Setting the Force Limits

In addition to setting the travel limits, it’s important to properly set the force limits on your Chamberlain Whisper Drive Plus opener. This ensures that the opener exerts the right amount of force during opening and closing. Here’s how to do it:

  • Locate the purple/yellow buttons on your Chamberlain Whisper Drive Plus opener.
  • To set the up/open force limit, press and hold the purple/yellow button until the up arrow LED starts flashing.
  • While the up arrow LED is flashing, press the button again to set the desired force limit for the up/open position.
  • To set the down/close force limit, press and hold the black button until the down arrow LED starts flashing.
  • While the down arrow LED is flashing, press the black button again to set the desired force limit for the down/close position.
  • Test the force settings by operating your garage door. If adjustments are needed, repeat the steps above.

Safety Precautions and Testing

When adjusting the travel and force limits, always prioritize safety. Improper adjustments can pose serious risks and cause damage to your garage door and opener. After making adjustments, thoroughly test the safety reversal system, which is designed to reverse the door’s movement if it comes into contact with an object or obstruction. Here’s how to test the system:

  • Open the garage door fully and place an object, such as a block of wood, in the doorway.
  • Activate the garage door opener to close the door.
  • Observe if the door stops and reverses its direction when it approaches the object.
  • If the door does not reverse, contact a professional technician for assistance.

Final Checks and Recommendations

After setting the travel and force limits, perform final checks to ensure everything is properly adjusted. Run the door through multiple open and close cycles to verify that it stops at the desired positions. If adjustments are needed, refer back to the specific instructions provided for your particular opener type.

Remember to prioritize safety when dealing with garage door travel limits. Regularly check the travel limits to ensure smooth operation and enhanced security.

Lap Pets: Airline Rules

You may want to see also

quartzmountain

Chamberlain/Liftmaster Security 2.0+ Technology: Adjusting the limits

Setting the travel limits on your Chamberlain Whisper Drive Plus is crucial for ensuring that your garage door stops at the right points when moving up or down. By properly setting these limits, you can enhance the security of your garage and ensure the door operates smoothly without any potential risks.

If you have a Chamberlain/Liftmaster opener with Security 2.0+ Technology, you can easily adjust the travel limits using the up and down arrow buttons on the back of the opener. Here is a step-by-step guide:

  • Start with the garage door in the down position.
  • Press and hold the adjustment button (the rectangular button between the Up and Down arrow buttons) until the Up Arrow button begins to blink.
  • Press and hold the Up Arrow button until the door reaches your desired open position. You can use both the Up and Down arrow buttons for adjustment.
  • When the garage door is in your desired open position, press and release the rectangular adjustment button. The garage door opener light will blink twice, and the Down arrow light will illuminate.
  • Press and hold the Down arrow button until the garage door reaches your desired closed position. You can use both the Up and Down Arrow buttons for adjustment.
  • When the garage door is in your desired closed position, press and release the rectangular adjustment button. The garage door opener light will blink twice, and the Up Arrow button will begin to blink.
  • Press and release the Up Arrow button. The door will open to the programmed open position, and then the Down Arrow button will begin to blink.
  • Press and release the Down Arrow button. The garage door will close to the programmed closed position.

By following these steps, you will complete the Travel and Force Limit adjustments for Chamberlain/Liftmaster Security 2.0+ Technology.

Advantages of Chamberlain/Liftmaster Security 2.0+ Technology:

This technology offers advanced features that enhance the security and convenience of your garage:

  • Secure radio frequency communication prevents hacking and unauthorized access to your garage.
  • Rolling code technology changes the access codes each time you use the remote control, eliminating code theft risks.
  • Compatibility with HomeLink in-vehicle remote control systems allows convenient operation of your garage door from your car.
  • Enhanced range and reliable performance ensure seamless operation.

quartzmountain

Older Chamberlain/Liftmaster: Programming the purple and black or black and yellow buttons

The purple and black or black and yellow buttons are used to program the travel and force limits of your Chamberlain/Liftmaster. Travel limits control how far the garage door will open and close, while force limits regulate the amount of force used during opening and closing. The black button controls the up/open movement, and the purple or yellow button controls the down/close movement.

To set the Up/Open Limit:

  • Start with the garage door in the Down/closed position.
  • Press and hold the black button until the yellow LED begins to blink, then release the black button.
  • Press and hold the black button until the door reaches your desired Up/Open position. Make sure the garage door opens far enough for your vehicle but not past the point where the bottom of the garage door is even with the header of the garage door opening.
  • You can adjust the open position using both the black button for open/up movement and purple or yellow button for down/close movement.
  • Press the wall button or the button programmed on the remote to set the Up/Open limit. The garage door will begin to close.
  • When the door begins to close, immediately press and release the black or purple/yellow button.

To set the Down/Closed Limit:

  • The door should be in the Up/Open position.
  • Press and hold the purple or yellow button until the garage door reaches your desired Down/Closed position.
  • When the garage door reaches the Down/Closed position, you can make adjustments using the black button for open movement and the purple/yellow button for down movement. Make sure the garage door is fully closed with the weather seal on the bottom of the door resting on the floor, but not so far closed that the opener rail is flexing upward toward the garage ceiling.
  • Press the wall button or the button programmed on the remote to set the Down/Closed limit. The garage door should begin to open to the programmed Open/Up position.

To set the Force Limits:

  • Press the purple/yellow button twice to enter the Force Adjustment Mode.
  • Press the wall button or the button programmed on the handheld remote. The garage door will close to the Down/Closed position.
  • Push the wall button or the button programmed on the remote a second time, and the garage door will open to the Up/Open position.
  • Push the wall button or the button programmed on the remote a third time, and the garage door will close to the Down/Closed position.
  • The yellow LED will stop blinking when the learn force has been set.

The force limit is self-adjusted during this process, and there are no other force adjustments required for this unit. The garage door opener must run through a complete open and close cycle for the force limit to be set properly.

quartzmountain

Older Chamberlain/Liftmaster: Setting travel limits with plastic screw adjustments

The first step is to locate the white travel limit adjustment screws, which are usually found on the side of the garage door opener motor. There will be two screws: one for the open travel limit and one for the close travel limit.

Next, ensure the garage door is closed and the trolley is attached to the garage door. Then, press the wall button or the button on the handheld remote to open the garage door. When the door is fully open, it should be at least 5 feet off the ground. The bottom of the garage door should not open past the header on the garage door opening, and you should have a minimum of 1 inch of clearance from the stop bolt on the opener rail.

Now, it's time to adjust the up/open limit. Using the up/open limit adjustment screw, turn the screw clockwise for more open travel and counter-clockwise for less open travel. One full turn of the adjustment screw will result in about 2 inches of travel adjustment. It is important to set the up/open travel limit correctly. If the door opens too far, it can cause damage to the opener, garage door, and potentially cause the door to go off track.

Once the open travel limit is set, you can move on to setting the down travel limit. Use the down/close adjustment screw, turning it clockwise to decrease the down travel and counter-clockwise to increase it. The proper fully closed position is when the seal on the bottom of the garage door rests on the floor. The door, when fully closed, should not reverse and return to the open position, and the operator rail should not flex up. If the door closes too far and does not reverse, it can cause damage to the garage door opener and the garage door.

Finally, run the door through 2-3 full open and close cycles to ensure the door opens and closes at the desired locations.

Compatible LiftMaster Models:

Chain Drive – 2245, 2255, 3245, 3255, 3245M, 3255M, 2265, 3265, 3265M, 2565, 2575, 3575, 3575S, 3275, 2595

quartzmountain

Chamberlain Whisper Drive Plus: Setting force limits

Setting the force limits on your Chamberlain Whisper Drive Plus is crucial to ensure your garage door operates smoothly and securely. Here's a detailed guide on how to set the force limits for your garage door opener:

Step 1: Identify the Purple/Yellow Buttons

The first step in setting the force limits is to locate the purple/yellow buttons on your Chamberlain Whisper Drive Plus opener. These buttons are essential for adjusting the force settings.

Step 2: Set the Up/Open Force Limit

To set the force limit for the up/open position, press and hold the purple/yellow button until the up arrow LED starts flashing. This indicates that you are now in the force adjustment mode.

Step 3: Adjust the Up/Open Force

While the up arrow LED is flashing, press the button again to set the desired force limit for the up/open position. This will determine the amount of force exerted by the opener when opening the garage door.

Step 4: Set the Down/Close Force Limit

To set the force limit for the down/close position, press and hold the black button until the down arrow LED starts flashing. This will allow you to adjust the force limit for the closing operation.

Step 5: Adjust the Down/Close Force

While the down arrow LED is flashing, press the black button again to set the desired force limit for the down/close position. This adjustment ensures that the opener exerts the appropriate force when closing the garage door.

Step 6: Test the Force Settings

After adjusting the force limits, it's important to test the garage door to ensure smooth and safe operation. Operate your garage door and observe if it opens and closes smoothly without encountering any excessive resistance. If the door doesn't operate as expected, repeat the above steps to readjust the force limits until you achieve the desired results.

Safety Precautions:

When adjusting the force limits, always prioritize safety. Improper adjustments can lead to safety risks and potential damage to your garage door and opener. Avoid using force adjustments to compensate for a sticking or binding garage door. Always follow the manufacturer's instructions and safety guidelines for the best results.

Final Checks:

Once you've set the force limits, perform final checks to ensure the garage door operates optimally. Run the door through multiple open and close cycles, observing if it stops at the desired positions. If adjustments are needed, refer back to the specific steps provided for your Chamberlain Whisper Drive Plus model and make the necessary changes.

Frequently asked questions

A:

To set the travel limits on your Chamberlain Whisper Drive Plus garage opener, follow these steps:

A:

For Chamberlain/Liftmaster openers with Security 2.0+ Technology, you can set the travel limits using the up and down arrow buttons on the back of the opener. First, press and hold the adjustment button until the Up Arrow button begins to blink. Then, use the up and down arrow buttons to adjust the door to your desired open and closed positions. Finally, press the adjustment button again to complete the process.

A:

For older Chamberlain/Liftmaster openers with purple and black or black and yellow buttons, you need to program the travel limits during the initial installation. To set the up position, press and hold the black button until the yellow LED starts blinking, then adjust the door to your desired position. To set the down position, hold the purple button until the door reaches the desired closed position and set the limit using the wall button or remote.

A:

For older Chamberlain/Liftmaster openers with plastic screw adjustments, locate the white travel limit adjustment screws on the side of the motor. Use the up/open limit adjustment screw to set the desired fully open position, and adjust the down/close limit using the corresponding screw.

Written by
Reviewed by
Share this post
Print
Did this article help you?

Leave a comment